 FEATURES

LTC2495 16-Bit 8-/16-Channel ADC with PGA, Easy Drive and I2C Interface DESCRIPTION
The LTC(R)2495 is a 16-channel (eight differential), 16-bit, No Latency TM ADC with Easy Drive technology and a 2-wire, I2C interface. The patented sampling scheme eliminates dynamic input current errors and the shortcomings of on-chip buffering through automatic cancellation of differential input current. This allows large external source impedances and rail-to-rail input signals to be directly digitized while maintaining exceptional DC accuracy. The LTC2495 includes programmable gain, a high accuracy temperature sensor, and an integrated oscillator. This device can be configured to measure an external signal (from combinations of 16 analog input channels operating in singleended or differential modes) or its internal temperature sensor. The integrated temperature sensor offers 1/2C resolution and 2C absolute accuracy. The LTC2495 can be configured to provide a programmable gain from 1 to 256 in 8 steps. The LTC2495 allows a wide common mode input range (0V to VCC), independent of the reference voltage. Any combination of single-ended or differential inputs can be selected and the first conversion, after a new channel is selected, is valid. Access to the multiplexer output enables optional external amplifiers to be shared between all analog inputs and auto calibration continuously removes their associated offset and drift.
, LT, LTC and LTM are registered trademarks of Linear Technology Corporation. No Latency and Easy Drive are trademarks of Linear Technology Corporation. All other trademarks are the property of their respective owners.
Up to Eight Differential or 16 Single-Ended Inputs Easy DriveTM Technology Enables Rail-to-Rail Inputs with Zero Differential Input Current Directly Digitizes High Impedance Sensors with Full Accuracy 2-Wire I2C Interface with 27 Addresses Plus One Global Address for Synchronization 600nV RMS Noise Programmable Gain from 1 to 256 Integrated High Accuracy Temperature Sensor GND to VCC Input/Reference Common Mode Range Programmable 50Hz, 60Hz, or Simultaneous 50Hz/ 60Hz Rejection Mode 2ppm INL, No Missing Codes 1ppm Offset and 15ppm Full-Scale Error 2x Speed/Reduced Power Mode (15Hz Using Internal Oscillator and 80A at 7.5Hz Output) No Latency: Digital Filter Settles in a Single Cycle, Even After a New Channel is Selected Single Supply 2.7V to 5.5V Operation (0.8mW) Internal Oscillator Tiny 5mm x 7mm QFN Package
APPLICATIONS

Direct Sensor Digitizer Direct Temperature Measurement Instrumentation Industrial Process Control
TYPICAL APPLICATION
Data Acquisition System with Temperature Compensation
2.7V TO 5.5V CH0 CH1 * * * CH7 CH8 16-CHANNEL MUX * * * CH15 COM TEMPERATURE SENSOR MUXOUT/ ADCIN REF + 16-BIT ADC WITH EASY DRIVE IN- REF - FO OSC
2495 TA01
Built-In High Performance Temperature Sensor
5 4 3 0.1F 10F ABSOLUTE ERROR (C)
VCC
2 1 0 -1 -2 -3 -4
IN+
1.7k SDA SCL 2-WIRE I2C INTERFACE
MUXOUT/ ADCIN
-5 -55
-30
-5 20 45 70 TEMPERATURE (C)
95
120
2495 TA02
2495f
1
LTC2495 ABSOLUTE MAXIMUM RATINGS
(Notes 1, 2)
PACKAGE/ORDER INFORMATION
TOP VIEW GND GND GND 31 GND 30 REF- 29 REF+ 28 VCC 27 MUXOUTN 39 26 ADCINN 25 ADCINP 24 MUXOUTP 23 CH15 22 CH14 21 CH13 20 CH12 13 14 15 16 17 18 19 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CA2 CA1 CA0 FO 38 37 36 35 34 33 32 GND 1 SCL 2 SDA 3 GND 4 NC 5 GND 6 COM 7 CH0 8 CH1 9 CH2 10 CH3 11 CH4 12
Supply Voltage (VCC) ................................... -0.3V to 6V Analog Input Voltage (CH0-CH15, COM) ....................-0.3V to (VCC + 0.3V) REF +, REF - ...............................-0.3V to (VCC + 0.3V) ADCINN, ADCINP, MUXOUTP, MUXOUTN ................................-0.3V to (VCC + 0.3V) Digital Input Voltage......................-0.3V to (VCC + 0.3V) Digital Output Voltage ...................-0.3V to (VCC + 0.3V) Operating Temperature Range LTC2495C ................................................. 0C to 70C LTC2495I ..............................................-40C to 85C Storage Temperature Range....................-65C to 150C
UHF PACKAGE 38-LEAD (5mm x 7mm) PLASTIC QFN TJMAX = 125C, JA = 34C/W EXPOSED PAD (PIN #39) IS GND, MUST BE SOLDERED TO PCB
ORDER PART NUMBER LTC2495CUHF LTC2495IUHF
QFN PART MARKING* 2495
Order Options Tape and Reel: Add #TR Lead Free: Add #PBF Lead Free Tape and Reel: Add #TRPBF Lead Free Part Marking: http://www.linear.com/leadfree/ Consult LTC Marketing for parts specified with wider operating temperature ranges. *The temperature grade is defined by a label on the shipping container.
2495f
2
LTC2495 ELECTRICAL CHARACTERISTICS (NORMAL SPEED)
PARAMETER Resolution (No Missing Codes) Integral Nonlinearity Offset Error Offset Error Drift Positive Full-Scale Error Positive Full-Scale Error Drift Negative Full-Scale Error Negative Full-Scale Error Drift Total Unadjusted Error CONDITIONS 0.1V VREF VCC, -FS VIN +FS (Note 5) 5V VCC 5.5V, VREF = 5V, VIN(CM) = 2.5V (Note 6) 2.7V VCC 5.5V, VREF = 2.5V, VIN(CM) = 1.25V (Note 6) 2.5V VREF VCC, GND IN+ = IN- VCC (Note 13) 2.5V VREF VCC, GND IN+ = IN- VCC 2.5V VREF VCC, IN+ = 0.75VREF , IN- = 0.25VREF 2.5V VREF VCC, IN+ = 0.75VREF , IN- = 0.25VREF 2.5V VREF VCC, IN+ = 0.25VREF , IN- = 0.75VREF 2.5V VREF VCC, IN+ = 0.25VREF , IN- = 0.75VREF 5V VCC 5.5V, VREF = 2.5V, VIN(CM) = 1.25V 5V VCC 5.5V, VREF = 5V, VIN(CM) = 2.5V 2.7V VCC 5.5V, VREF = 2.5V, VIN(CM) = 1.25V 2.7V < VCC < 5.5V, 2.5V VREF VCC, GND IN+ = IN- VCC (Note 12) TA = 27C (Note 13)

The denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. (Notes 3, 4)
MIN 16 2 1 0.5 10 32 0.1 32 0.1 15 15 15 0.6 27.8 1 28.0 93.5 256 28.2 20 5 TYP MAX UNITS Bits ppm of VREF ppm of VREF V nV/C ppm of VREF ppm of VREF/C ppm of VREF ppm of VREF/C ppm of VREF ppm of VREF ppm of VREF VRMS mV V/C
Output Noise Internal PTAT Signal Internal PTAT Temperature Coefficient Programmable Gain
ELECTRICAL CHARACTERISTICS (2X SPEED)
PARAMETER Resolution (No Missing Codes) Integral Nonlinearity Offset Error Offset Error Drift Positive Full-Scale Error Positive Full-Scale Error Drift Negative Full-Scale Error Negative Full-Scale Error Drift Output Noise Programmable Gain CONDITIONS 0.1V VREF VCC, -FS VIN +FS (Note 5)
The denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. (Notes 3, 4)
MIN 16

TYP 2 1 0.2 100
MAX 20 2 32
UNITS Bits ppm of VREF ppm of VREF mV nV/C ppm of VREF ppm of VREF/C ppm of VREF ppm of VREF/C VRMS
5V VCC 5.5V, VREF = 5V, VIN(CM) = 2.5V (Note 6) 2.7V VCC 5.5V, VREF = 2.5V, VIN(CM) = 1.25V (Note 6) 2.5V VREF VCC, GND IN+ = IN- VCC (Note 13) 2.5V VREF VCC, GND IN+ = IN- VCC 2.5V VREF VCC, IN+ = 0.75VREF , IN- = 0.25VREF 2.5V VREF VCC, IN+ = 0.75VREF , IN- = 0.25VREF 2.5V VREF VCC, IN+ = 0.25VREF , IN- = 0.75VREF 2.5V VREF VCC, IN+ = 0.25VREF , IN- = 0.75VREF 5V VCC 5.5V, VREF = 5V, GND IN+ = IN- VCC
0.1
32 0.1 0.85
1
128
CONVERTER CHARACTERISTICS
PARAMETER Input Common Mode Rejection DC Input Common Mode Rejection 50Hz 2% Input Common Mode Rejection 60Hz 2% Input Normal Mode Rejection 50Hz 2% Input Normal Mode Rejection 60Hz 2% Input Normal Mode Rejection 50Hz/60Hz 2% Reference Common Mode Rejection DC Power Supply Rejection DC Power Supply Rejection, 50Hz 2%, 60Hz 2% CONDITIONS
The denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. (Note 3)
MIN

TYP
MAX
UNITS dB dB dB
2.5V VREF VCC, GND IN+ = IN- VCC (Note 5) 2.5V VREF VCC, GND IN+ = IN- VCC (Notes 5, 7) 2.5V VREF VCC, GND IN+ = IN- VCC (Notes 5, 8) 2.5V VREF VCC, GND IN+ = IN- VCC (Notes 5, 7) 2.5V VREF VCC, GND IN+ = IN- VCC (Notes 5, 8) 2.5V VREF VCC, GND IN+ = IN- VCC (Notes 5, 9) 2.5V VREF VCC, GND IN+ = IN- VCC (Note 5) VREF = 2.5V, IN+ = IN- = GND VREF = 2.5V, IN+ = IN- = GND (Notes 7, 8, 9)
140 140 140 110 110 87 120 140 120 120 120 120
dB dB dB dB dB dB
2495f
3
LTC2495 ANALOG INPUT AND REFERENCE
SYMBOL IN+ IN- VIN FS LSB REF+ REF- VREF CS(IN+) CS(IN-) CS(VREF) IDC_LEAK(IN+)
-
The denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. (Note 3)
PARAMETER Absolute/Common Mode IN+ Voltage (IN+ Corresponds to the Selected Positive Input Channel) Absolute/Common Mode IN- Voltage (IN- Corresponds to the Selected Negative Input Channel) Input Differential Voltage Range (IN+ - IN-) Full Scale of the Differential Input (IN+ - IN-) Least Significant Bit of the Output Code Absolute/Common Mode REF+ Voltage Absolute/Common Mode REF- Voltage Reference Voltage Range (REF+ - REF-) IN+ Sampling Capacitance IN- Sampling Capacitance VREF Sampling Capacitance IN+ DC Leakage Current IN- DC Leakage Current Sleep Mode, IN+ = GND Sleep Mode, IN- = GND Sleep Mode, REF+ = V
CC
CONDITIONS
MIN GND - 0.3V GND - 0.3V

TYP
MAX VCC + 0.3V VCC + 0.3V +FS
UNITS V V V V
-FS 0.5VREF/Gain FS/216 0.1 GND 0.1 11 11 11
VCC REF+ - 0.1V VCC
V V V pF pF pF

-10 -10 -100 -100
1 1 1 1 50 120
10 10 100 100
nA nA nA nA ns dB
IDC_LEAK(IN ) IDC_LEAK(REF+) REF+ DC Leakage Current IDC_LEAK(REF-) REF- DC Leakage Current tOPEN QIRR MUX Break-Before-Make MUX Off Isolation
Sleep Mode, REF- = GND VIN = 2VP-P DC to 1.8MHz
I2C INPUTS AND DIGITAL OUTPUTS
SYMBOL VIH VIL VIHA VILA RINH RINL RINF II VHYS VOL tOF IIN CCAX PARAMETER High Level Input Voltage Low Level Input Voltage Low Level Input Voltage for Address Pins CA0, CA1, CA2 High Level Input Voltage for Address Pins CA0, CA1, CA2 Resistance from CA0, CA1, CA2 to VCC to Set Chip Address Bit to 1 Resistance from CA0, CA1, CA2 to GND to Set Chip Address Bit to 0 Resistance from CA0, CA1, CA2 to GND or VCC to Set Chip Address Bit to Float Digital Input Current (FO) Hysteresis of Schmitt Trigger Inputs Low Level Output Voltage (SDA) Output Fall Time VIH(MIN) to VIL(MAX) Input Leakage (SDA/SCL) External Capacitative Load on Chip Address Pins (CA0, CA1, CA2) for Valid Float
The denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. (Note 3)
CONDITIONS

MIN 0.7VCC
TYP
MAX 0.3VCC 0.05VCC
UNITS V V V V k k M
0.95VCC 10 10 2 -10 0.05VCC 0.4 20 + 0.1CB 250 1 10 10
A V V ns A pF
(Note 5) I = 3mA Bus Load CB 10pF to 400pF (Note 14) 0.1VCC VIN 0.9 * VCC

2495f
4
LTC2495 POWER REQUIREMENTS
SYMBOL VCC ICC PARAMETER Supply Voltage Supply Current Conversion Current (Note 11) Temperature Measurement (Note 11) Sleep Mode (Note 11)
The denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. (Note 3)
CONDITIONS

MIN 2.7
TYP 160 200 1
MAX 5.5 275 300 2
UNITS V A A A
DIGITAL INPUTS AND DIGITAL OUTPUTS
SYMBOL fEOSC tHEO tLEO tCONV_1 PARAMETER External Oscillator Frequency Range External Oscillator High Period External Oscillator Low Period Conversion Time for 1x Speed Mode CONDITIONS (Note 16)
The denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. (Note 3)
MIN

TYP
MAX 4000 100 100
UNITS kHz s s ms ms ms ms ms ms ms ms
10 0.125 0.125 157.2 131 144.1 78.7 65.6 72.2 160.3 133.6 146.9 41036/fEOSC (in kHz) 80.3 66.9 73.6 20556/fEOSC (in kHz)
50Hz Mode 60Hz Mode Simultaneous 50Hz/60Hz Mode External Oscillator (Note 10) 50Hz Mode 60Hz Mode Simultaneous 50Hz/60Hz Mode External Oscillator (Note 10)

163.5 136.3 149.9 81.9 68.2 75.1
tCONV_2
Conversion Time for 2x Speed Mode
I2C TIMING CHARACTERISTICS
SYMBOL fSCL tHD(SDA) tLOW tHIGH tSU(STA) tHD(DAT) tSU(DAT) tr tf tSU(STO) tBUF PARAMETER SCL Clock Frequency Hold Time (Repeated) Start Condition Low Period of the SCL Pin High Period of the SCL Pin Set-Up Time for a Repeated Start Condition Data Hold Time Data Set-Up Time Rise Time for SDA Signals Fall Time for SDA Signals Set-Up Time for Stop Condition Bus Free Time Between a Second Start Condition
The denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. (Note 3, 15)
CONDITIONS

MIN 0 0.6 1.3 0.6 0.6 0 100 20 + 0.1CB 20 + 0.1CB 0.6 1.3
TYP
MAX 400
UNITS kHz s s s s
0.9 300 300
s ns ns ns s s
(Note 14) (Note 14)

Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: All voltage values are with respect to GND. Note 3: Unless otherwise specified: VCC = 2.7V to 5.5V VREFCM = VREF/2, FS = 0.5VREF/Gain VIN = IN+ - IN-, VIN(CM) = (IN+ - IN-)/2, where IN+ and IN- are the selected input channels. Note 4: Use internal conversion clock or external conversion clock source with fEOSC = 307.2kHz unless otherwise specified. Note 5: Guaranteed by design, not subject to test. Note 6: Integral nonlinearity is defined as the deviation of a code from a straight line passing through the actual endpoints of the transfer curve. The deviation is measured from the center of the quantization band.
Note 7: 50Hz mode (internal oscillator) or fEOSC = 256kHz 2% (external oscillator). Note 8: 60Hz mode (internal oscillator) or fEOSC = 307.2kHz 2% (external oscillator). Note 9: Simultaneous 50Hz/60Hz mode (internal oscillator) or fEOSC = 280kHz 2% (external oscillator). Note 10: The external oscillator is connected to the FO pin. The external oscillator frequency, fEOSC, is expressed in kHz. Note 11: The converter uses its internal oscillator. Note 12: The output noise includes the contribution of the internal calibration operations. Note 13: Guaranteed by design and test correlation. Note 14: CB = capacitance of one bus line in pF (10pF CB 400pF). Note 15: All values refer to VIH(MIN) and VIL(MAX) levels. Note 16: Refer to Applications Information section for Performance vs Data Rate graphs.
2495f
5
LTC2495 TYPICAL PERFORMANCE CHARACTERISTICS
Integral Nonlinearity (VCC = 5V, VREF = 5V)
3 2 INL (ppm of VREF) 1 0 85C -1 -2 -3 -2.5 -2 -1.5 -1 -0.5 0 0.5 1 1.5 INPUT VOLTAGE (V) VCC = 5V VREF = 5V VIN(CM) = 2.5V FO = GND INL (ppm of VREF) -45C 25C 3 2 1 -45C, 25C, 85C 0 -1 -2 -3 -1.25
Integral Nonlinearity (VCC = 5V, VREF = 2.5V)
VCC = 5V VREF = 2.5V VIN(CM) = 1.25V FO = GND INL (ppm of VREF) 3 2 1
Integral Nonlinearity (VCC = 2.7V, VREF = 2.5V)
VCC = 2.7V VREF = 2.5V VIN(CM) = 1.25V FO = GND -45C, 25C, 85C 0 -1 -2 -3 -1.25
2
2.5
-0.75
-0.25 0.25 0.75 INPUT VOLTAGE (V)
1.25
2495 G02
-0.75
-0.25 0.25 0.75 INPUT VOLTAGE (V)
1.25
2495 G03
2495 G01
Total Unadjusted Error (VCC = 5V, VREF = 5V)
12 8 TUE (ppm of VREF) 4 0 -4 -8 -12 -2.5 -2 -1.5 -1 -0.5 0 0.5 1 1.5 INPUT VOLTAGE (V) -45C VCC = 5V VREF = 5V VIN(CM) = 2.5V FO = GND 12 8 85C TUE (ppm of VREF) 25C 4 0 -4 -8
Total Unadjusted Error (VCC = 5V, VREF = 2.5V)
VCC = 5V VREF = 2.5V VIN(CM) = 1.25V FO = GND 12 85C 25C TUE (ppm of VREF) 4 0 -4 -8 8
Total Unadjusted Error (VCC = 2.7V, VREF = 2.5V)
VCC = 2.7V VREF = 2.5V VIN(CM) = 1.25V FO = GND
25C
85C
-45C
-45C
2
2.5
-12 -1.25
-0.75
-0.25 0.25 0.75 INPUT VOLTAGE (V)
1.25
2495 G05
-12 -1.25
-0.75
-0.25 0.25 0.75 INPUT VOLTAGE (V)
1.25
2495 G06
2495 G04
Noise Histogram (6.8sps)
14 12 NUMBER OF READINGS (%) 10,000 CONSECUTIVE READINGS RMS = 0.60V VCC = 5V AVERAGE = -0.69V VREF = 5V 10 VIN = 0V TA = 25C 8 GAIN = 256 6 4 2 0 -3 -2.4 -1.8 -1.2 -0.6 0 0.6 OUTPUT READING (V) 1.2 1.8 14 12 NUMBER OF READINGS (%)
Noise Histogram (7.5sps)
10,000 CONSECUTIVE READINGS RMS = 0.59V VCC = 2.7V AVERAGE = -0.19V VREF = 2.5V 10 VIN = 0V TA = 25C 8 GAIN = 256 6 4 2 0 -3 -2.4 -1.8 -1.2 -0.6 0 0.6 OUTPUT READING (V) 1.2 1.8 5 4 3 ADC READING (V) 2 1 0 -1 -2 -3 -4 -5
Long-Term ADC Readings
TA = 25C VCC = 5V VREF = 5V RMS NOISE = 0.60V VIN = 0V GAIN = 256 VIN(CM) = 2.5V
0
10
30 40 20 TIME (HOURS)
50
60
2495 G09
2495 G07
2495 G08
2495f
6
LTC2495 TYPICAL PERFORMANCE CHARACTERISTICS
RMS Noise vs Input Differential Voltage
1.0 0.9 RMS NOISE (V) 0.8 0.7 0.6 0.5 0.4 -2.5 -2 -1.5 -1 -0.5 0 0.5 1 1.5 2 INPUT DIFFERENTIAL VOLTAGE (V) 1.0 VCC = 5V VREF = 5V VIN(CM) = 2.5V TA = 25C FO = GND 0.9 RMS NOISE (V) 0.8 0.7 0.6 0.5 0.4 2.5 -1 0 1 2 3 4 5 6
2495 G11
RMS Noise vs VIN(CM)
VCC = 5V VREF = 5V VIN = 0V TA = 25C FO = GND GAIN = 256 1.0
RMS Noise vs Temperature (TA)
VCC = 5V VREF = 5V 0.9 VIN = 0V VIN(CM) = GND FO = GND 0.8 GAIN = 256 0.7 0.6 0.5 0.4 -45 -30 -15
RMS NOISE (V)
VIN(CM) (V)
0 15 30 45 60 TEMPERATURE (C)
75
90
2495 G10
2495 G12
RMS Noise vs VCC
1.0 0.9 RMS NOISE (V) 0.8 0.7 0.6 0.5 0.4 2.7 VREF = 2.5V VIN = 0V VIN(CM) = GND TA = 25C FO = GND GAIN = 256 1.0 0.9 RMS NOISE (V) 0.8 0.7 0.6 0.5 0.4 3.1 3.5 3.9 4.3 VCC (V) 4.7 5.1 5.5
RMS Noise vs VREF
VCC = 5V VIN = 0V VIN(CM) = GND TA = 25C FO = GND GAIN = 256 0.3 0.2 0.1 0 -0.1 -0.2 -0.3 0 1 2 3 VREF (V) 4 5
2495 G14
Offset Error vs VIN(CM)
VCC = 5V VREF = 5V VIN = 0V TA = 25C FO = GND
OFFSET ERROR (ppm of VREF)
-1
0
1
3 2 VIN(CM) (V)
4
5
6
2495 G15
2495 G13
Offset Error vs Temperature
0.3 0.2 0.1 0 VCC = 5V VREF = 5V VIN = 0V VIN(CM) = GND FO = GND 0.3 0.2 0.1 0 -0.1 -0.2
Offset Error vs VCC
REF+ = 2.5V REF- = GND VIN = 0V VIN(CM) = GND TA = 25C FO = GND 0.3 0.2 0.1 0
Offset Error vs VREF
VCC = 5V REF - = GND VIN = 0V VIN(CM) = GND TA = 25C FO = GND
OFFSET ERROR (ppm of VREF)
-0.1 -0.2
OFFSET ERROR (ppm of VREF)
-0.3 -45 -30 -15
0 15 30 45 60 TEMPERATURE (C)
75
90
-0.3 2.7
OFFSET ERROR (ppm of VREF)
-0.1 -0.2
-0.3 3.1 3.5 3.9 4.3 VCC (V) 4.7 5.1 5.5 0 1 2 3 VREF (V) 4 5
2495 G18
2495 G16
2495 G17
2495f
7
LTC2495 TYPICAL PERFORMANCE CHARACTERISTICS
On-Chip Oscillator Frequency vs Temperature
310 310
On-Chip Oscillator Frequency vs VCC
0 -20 308 FREQUENCY (kHz) -40 306 REJECTION (dB) -60 -80 -100 -120 -140
PSRR vs Frequency at VCC
VCC = 4.1V DC VREF = 2.5V IN+ = GND IN- = GND FO = GND TA = 25C
308 FREQUENCY (kHz)
306
304 VCC = 4.1V VREF = 2.5V VIN = 0V VIN(CM) = GND FO = GND 0 15 30 45 60 TEMPERATURE (C) 75 90
304 VREF = 2.5V VIN = 0V VIN(CM) = GND FO = GND TA = 25C 2.5 3.0 3.5 4.0 VCC (V) 4.5 5.0 5.5
2495 G20
302
302
300 -45 -30 -15
300
1
10
10k 100k 1k 100 FREQUENCY AT VCC (Hz)
1M
2495 G19
2495 G21
PSRR vs Frequency at VCC
0 -20 -40 REJECTION (dB) -60 -80 -100 -120 -140 0 20 40 60 80 100 120 140 160 180 200 220 FREQUENCY AT VCC (Hz)
2495 G22
PSRR vs Frequency at VCC
VCC = 4.1V DC 0.7V VREF = 2.5V -20 IN+ = GND IN- = GND -40 FO = GND TA = 25C -60 -80 -100 -120 -140 30600 0 200
Conversion Current vs Temperature
FO = GND
CONVERSION CURRENT (A)
REJECTION (dB)
VCC = 4.1V DC 1.4V VREF = 2.5V IN+ = GND IN- = GND FO = GND TA = 25C
180 VCC = 5V 160 VCC = 2.7V
140
120
30650
30750 FREQUENCY AT VCC (Hz)
30700
30800
2495 G23
100 -45 -30 -15
0 15 30 45 60 TEMPERATURE (C)
75
90
2495 G24
Sleep Mode Current vs Temperature
2.0 1.8 SLEEP MODE CURRENT (A) 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 -45 -30 -15 0 15 30 45 60 TEMPERATURE (C) 75 90 VCC = 2.7V VCC = 5V SUPPLY CURRENT (A) FO = GND 500
Conversion Current vs Output Data Rate
VREF = VCC + 450 IN- = GND IN = GND 400 FO = EXT OSC TA = 25C 350 300 250 200 150 100 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 G26
Integral Nonlinearity (2x Speed Mode; VCC = 5V, VREF = 5V)
3 2 VCC = 5V INL (V) 1 0 -1 -45C -2 -3 -2.5 -2 -1.5 -1 -0.5 0 0.5 1 1.5 INPUT VOLTAGE (V) 25C, 85C VCC = 5V VREF = 5V VIN(CM) = 2.5V FO = GND
VCC = 3V
2
2.5
2495 G25
2495 G27
2495f
8
LTC2495 TYPICAL PERFORMANCE CHARACTERISTICS
Integral Nonlinearity (2x Speed Mode; VCC = 5V, VREF = 2.5V)
3 2 INL (ppm OF VREF) 1 85C 0 -1 -2 -3 -1.25 -45C, 25C VCC = 5V VREF = 2.5V VIN(CM) = 1.25V FO = GND INL (ppm OF VREF) 3 2 1 85C 0 -1 -2 2 -0.75 -0.25 0.25 0.75 INPUT VOLTAGE (V) 1.25
2495 G28
Integral Nonlinearity (2x Speed Mode; VCC = 2.7V, VREF = 2.5V)
VCC = 2.7V VREF = 2.5V VIN(CM) = 1.25V FO = GND 16
Noise Histogram (2x Speed Mode)
RMS = 0.85V 10,000 CONSECUTIVE AVERAGE = 0.184mV 14 READINGS VCC = 5V 12 VREF = 5V VIN = 0V T = 25C 10 A GAIN = 128 8 6 4
-45C, 25C
-3 -1.25
NUMBER OF READINGS (%) 1.25
2495 G29
-0.75
-0.25 0.25 0.75 INPUT VOLTAGE (V)
0 179
181.4
183.8 186.2 OUTPUT READING (V)
188.6
2495 G30
RMS Noise vs VREF (2x Speed Mode)
1.0 200 198 0.8 OFFSET ERROR (V) RMS NOISE (V) 196 194 192 190 188 186 184 182 3 2 VREF (V) 4 5
2495 G31
Offset Error vs VIN(CM) (2x Speed Mode)
VCC = 5V VREF = 5V VIN = 0V FO = GND TA = 25C 240 230 OFFSET ERROR (V) 220 210 200 190 180 170 -1 0 1 3 VIN(CM) (V) 2 4 5 6
2495 G32
Offset Error vs Temperature (2x Speed Mode)
VCC = 5V VREF = 5V VIN = 0V VIN(CM) = GND FO = GND
0.6
0.4 VCC = 5V VIN = 0V VIN(CM) = GND FO = GND TA = 25C GAIN = 128 0 1
0.2
0
180
160 -45 -30 -15
0 15 30 45 60 TEMPERATURE (C)
75
90
2495 G33
Offset Error vs VCC (2x Speed Mode)
250 VREF = 2.5V VIN = 0V VIN(CM) = GND FO = GND TA = 25C 240 230 OFFSET ERROR (V) 220 210 200 190 180 170 0 2 2.5 3 4 3.5 VCC (V) 4.5 5 5.5
2495 G34
Offset Error vs VREF (2x Speed Mode)
VCC = 5V VIN = 0V VIN(CM) = GND FO = GND TA = 25C
200 OFFSET ERROR (V)
150
100
50
160
0
1
2
3 VREF (V)
4
5
2495 G35
2495f
9
LTC2495 TYPICAL PERFORMANCE CHARACTERISTICS
PSRR vs Frequency at VCC (2x Speed Mode)
0 -20 -40 REJECTION (dB) -60 -80 -100 -120 -140 1 10 10k 100k 1k 100 FREQUENCY AT VCC (Hz) 1M VCC = 4.1V DC REF+ = 2.5V REF- = GND IN+ = GND IN- = GND FO = GND TA = 25C 0 -20 -40 -60 -80 -100 -120 -140 0 20 40 60 80 100 120 140 160 180 200 220 FREQUENCY AT VCC (Hz)
2495 G37
PSRR vs Frequency at VCC (2x Speed Mode)
VCC = 4.1V DC 1.4V REF+ = 2.5V REF- = GND IN+ = GND IN- = GND FO = GND TA = 25C 0 -20
PSRR vs Frequency at VCC (2x Speed Mode)
VCC = 4.1V DC 0.7V REF+ = 2.5V REF- = GND IN+ = GND -40 IN- = GND FO = GND -60 TA = 25C -80 -100 -120 -140 30600
RREJECTION (dB)
REJECTION (dB)
30650
30700 30750 FREQUENCY AT VCC (Hz)
30800
2495 G38
2495 G36
PIN FUNCTIONS
GND (Pins 1, 4, 6, 31, 32, 33, 34): Ground. Multiple ground pins internally connected for optimum ground current flow and VCC decoupling. Connect each one of these pins to a common ground plane through a low impedance connection. All seven pins must be connected to ground for proper operation. SCL (Pin 2): Serial Clock Pin of the I2C Interface. The LTC2495 can only act as a slave and the SCL pin only accepts an external serial clock. Data is shifted into the SDA pin on the rising edges of the SCL clock and output through the SDA pin on the falling edges of the SCL clock. SDA (Pin 3): Bidirectional Serial Data Line of the I2C Interface. In the transmitter mode (Read), the conversion result is output through the SDA pin, while in the receiver mode (Write), the device channel select and configuration bits are input through the SDA pin. The pin is high impedance during the data input mode and is an open drain output (requires an appropriate pull-up device to VCC) during the data output mode. NC (Pin 5): No Connect. This pin can be left floating or tied to GND. COM (Pin 7): The Common Negative Input (IN -) for All Single-Ended Multiplexer Configurations. The voltage on CH0-CH15 and COM pins can have any value between GND - 0.3V to VCC + 0.3V. Within these limits, the two selected inputs (IN+ and IN- ) provide a bipolar input range VIN = (IN+ - IN-) from -0.5 * VREF/Gain to 0.5 * VREF /Gain. Outside this input range, the converter produces unique over-range and under-range output codes. CH0 to CH15 (Pin 8-Pin 23): Analog Inputs. May be programmed for single-ended or differential mode. MUXOUTP (Pin 24): Positive Multiplexer Output. Connect to the input of external buffer/amplifier or short directly to ADCINP. ADCINP (Pin 25): Positive ADC Input. Connect to the output of a buffer/amplifier driven by MUXOUTP or short directly to MUXOUTP.
2495f
10
LTC2495 PIN FUNCTIONS
ADCINN (Pin 26): Negative ADC Input. Connect to the output of a buffer/amplifier driven by MUXOUTN or short directly to MUXOUTN. MUXOUTN (Pin 27): Negative Multiplexer Output. Connect to the input of an external buffer/amplifier or short directly to ADCINN. VCC (Pin 28): Positive Supply Voltage. Bypass to GND with a 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor as close to the part as possible. REF+, REF - (Pin 29, Pin 30): Differential Reference Input. The voltage on these pins can have any value between GND and VCC as long as the reference positive input, REF+, remains more positive than the negative reference input, REF-, by at least 0.1V. The differential voltage (VREF = REF+ - REF -) sets the full-scale range (-0.5 * VREF/Gain to 0.5 * VREF/Gain) for all input channels. FO (Pin 35): Frequency Control Pin. Digital input that controls the internal conversion clock rate. When FO is connected to GND, the converter uses its internal oscillator running at 307.2kHz. The conversion clock may also be overridden by driving the FO pin with an external clock in order to change the output rate and the digital filter rejection null. CA0, CA1, CA2 (Pins 36, 37, 38): Chip Address Control Pins. These pins are configured as a three-state (LOW, HIGH, Floating) address control bits for the device I2C address. Exposed Pad (Pin 39): Ground. This pin is ground and must be soldered to the PCB ground plane. For prototyping purposes, this pin may remain floating.
FUNCTIONAL BLOCK DIAGRAM
TEMP SENSOR VCC GND REF + REF - CH0 CH1 * * * MUX MUXOUTP ADCINP AUTOCALIBRATION AND CONTROL INTERNAL OSCILLATOR FO (INT/EXT)
-
+
I2C 2-WIRE INTERFACE DECIMATING FIR ADDRESS
2495 BD
CH15 COM
DIFFERENTIAL 3RD ORDER MODULATOR
SDA SCL
MUXOUTN ADCINN
2495f
11
LTC2495 APPLICATIONS INFORMATION
CONVERTER OPERATION Converter Operation Cycle The LTC2495 is a multichannel, low power, delta-sigma, analog-to-digital converter with a 2-wire, I2C interface. Its operation is made up of four states (see Figure 1). The converter operating cycle begins with the conversion, followed by the sleep state, and ends with the data input/output cycle. Initially, at power-up, the LTC2495 performs a conversion. Once the conversion is complete, the device enters the sleep state. While in the sleep state, power consumption is reduced by two orders of magnitude. The part remains in the sleep state as long it is not addressed for a read/write operation. The conversion result is held indefinitely in a static shift register while the part is in the sleep state. The device will not acknowledge an external request during the conversion state. After a conversion is finished, the device is ready to accept a read/write request. Once the LTC2495 is addressed for a read operation, the device begins outputting the conversion result under the control of the serial clock (SCL). There is no latency in the conversion result. The data output is 24 bits long and contains a 16-bit plus sign conversion result. Data is updated on the falling edges of SCL allowing the user to reliably latch data on the rising edge of SCL. A new conversion is initiated by a stop condition following a valid write operation or an incomplete read operation. The conversion automatically begins at the conclusion of a complete read cycle (all 24 bits read out of the device). Ease of Use The LTC2495 data output has no latency, filter settling delay, or redundant data associated with the conversion cycle. There is a one-to-one correspondence between the conversion and the output data. Therefore, multiplexing multiple analog inputs is straightforward. Each conversion, immediately following a newly selected input or mode, is valid and accurate to the full specifications of the device. The LTC2495 automatically performs offset and full-scale calibration every conversion cycle independent of the input channel selected. This calibration is transparent to the user
POWER-ON RESET DEFAULT CONFIGURATION: IN+ = CH0, IN- = CH1 50Hz/60Hz REJECTION 1X OUTPUT, GAIN = 1
CONVERSION
SLEEP
NO
ACKNOWLEDGE
YES
DATA OUTPUT/INPUT
NO
STOP OR READ 24 BITS YES
2495 F01
Figure 1. State Transition Table
and has no effect on the operation cycle described above. The advantage of continuous calibration is extreme stability of offset and full-scale readings with respect to time, supply voltage variation, input channel, and temperature drift. Easy Drive Input Current Cancellation The LTC2495 combines a high precision, delta-sigma ADC with an automatic, differential, input current cancellation front end. A proprietary front end passive sampling network transparently removes the differential input current. This enables external RC networks and high impedance sensors to directly interface to the LTC2495 without external amplifiers. The remaining common mode input current is eliminated by either balancing the differential input impedances or setting the common mode input equal to the common mode reference (see the Automatic Differential Input Current Cancellation section). This unique architecture does not require on-chip buffers, thereby enabling signals to swing beyond ground and VCC. Moreover, the
2495f
12
LTC2495 APPLICATIONS INFORMATION
cancellation does not interfere with the transparent offset and full-scale auto-calibration and the absolute accuracy (full scale + offset + linearity + drift) is maintained even with external RC networks. Power-Up Sequence The LTC2495 automatically enters an internal reset state when the power supply voltage, VCC, drops below a threshold of approximately 2.0V. This feature guarantees the integrity of the conversion result and input channel selection. When VCC rises above this threshold, the converter creates an internal power-on-reset (POR) signal with a duration of approximately 4ms. The POR signal clears all internal registers. The conversion immediately following a POR cycle is performed on the input channels IN+ = CH0 and IN - = CH1 with simultaneous 50Hz/60Hz rejection, 1x output rate, and gain = 1. The first conversion following a POR cycle is accurate within the specification of the device if the power supply voltage is restored to (2.7V to 5.5V) before the end of the POR interval. A new input channel, rejection mode, speed mode, temperature selection or gain can be programmed into the device during this first data input/output cycle. Reference Voltage Range This converter accepts a truly differential external reference voltage. The absolute/common mode voltage range for the REF+ and REF - pins covers the entire operating range of the device (GND to VCC). For correct converter operation, VREF must be positive (REF+ > REF -). The LTC2495 differential reference input range is 0.1V to VCC. For the simplest operation, REF+ can be shorted to VCC and REF - can be shorted to GND. The converter output noise is determined by the thermal noise of the front end circuits and, as such, its value in nanovolts is nearly constant with reference voltage. A decrease in reference voltage will not significantly improve the converter's effective resolution. On the other hand, a decreased reference will improve the converter's overall INL performance. Input Voltage Range The analog inputs are truly differential with an absolute, common mode range for the CH0-CH15 and COM input pins extending from GND - 0.3V to VCC + 0.3V. Outside these limits, the ESD protection devices begin to turn on and the errors due to input leakage current increase rapidly. Within these limits, the LTC2495 converts the bipolar differential input signal VIN = IN+ - IN- (where IN+ and IN - are the selected input channels), from - FS = - 0.5 * VREF/Gain to + FS = 0.5 * VREF/Gain where VREF = REF+ - REF-. Outside this range, the converter indicates the overrange or the underrange condition using distinct output codes (see Table 1). Signals applied to the input (CH0-CH15, COM) may extend 300mV below ground and above VCC. In order to limit any fault current, resistors of up to 5k may be added in series with the input. The effect of series resistance on the converter accuracy can be evaluated from the curves presented in the Input Current/Reference Current sections. In addition, series resistors will introduce a temperature dependent error due to input leakage current. A 1nA input leakage current will develop a 1ppm offset error on a 5k resistor if VREF = 5V. This error has a very strong temperature dependency. MUXOUT/ADCIN The outputs of the multiplexer (MUXOUTP/MUXOUTN) and the inputs to the ADC (ADCINP/ADCINN) can be used to perform input signal conditioning on any of the selected input channels or simply shorted together for direct digitization. If an external amplifier is used, the LTC2495 automatically calibrates both the offset and drift of this circuit and the Easy Drive sampling scheme enables a wide variety of amplifiers to be used. In order to achieve optimum performance, if an external amplifier is not used, short these pins directly together (ADCINP to MUXOUTP and ADCINN to MUXOUTN) and minimize their capacitance to ground.
2495f
13
LTC2495 APPLICATIONS INFORMATION
I2C INTERFACE The LTC2495 communicates through an I2C interface. The I2C interface is a 2-wire, open-drain interface supporting multiple devices and multiple masters on a single bus. The connected devices can only pull the data line (SDA) low and can never drive it high. SDA is required to be externally connected to the supply through a pull-up resistor. When the data line is not being driven, it is high. Data on the I2C bus can be transferred at rates up to 100kbits/s in the standard mode and up to 400kbits/s in the fast mode. Each device on the I2C bus is recognized by a unique address stored in that device and can operate either as a transmitter or receiver, depending on the function of the device. In addition to transmitters and receivers, devices can also be considered as masters or slaves when performing data transfers. A master is the device which initiates a data transfer on the bus and generates the clock signals to permit that transfer. Devices addressed by the master are considered a slave. The LTC2495 can only be addressed as a slave. Once addressed, it can receive configuration bits (channel selection, rejection mode, speed mode) or transmit the last conversion result. The serial clock line, SCL, is always an input to the LTC2495 and the serial data line SDA is bidirectional. The device supports the standard mode and the fast mode for data transfer speeds up to 400kbits/s. Figure 2 shows the definition of the I2C timing. The Start and Stop Conditions A Start (S) condition is generated by transitioning SDA from high to low while SCL is high. The bus is considered to be busy after the Start condition. When the data transfer is finished, a Stop (P) condition is generated by transitioning SDA from low to high while SCL is high. The bus is free after a Stop is generated. Start and Stop conditions are always generated by the master. When the bus is in use, it stays busy if a Repeated Start (Sr) is generated instead of a Stop condition. The repeated Start timing is functionally identical to the Start and is used for writing and reading from the device before the initiation of a new conversion. Data Transferring After the Start condition, the I2C bus is busy and data transfer can begin between the master and the addressed slave. Data is transferred over the bus in groups of nine bits, one byte followed by one acknowledge (ACK) bit. The master releases the SDA line during the ninth SCL clock cycle. The slave device can issue an ACK by pulling SDA low or issue a Not Acknowledge (NAK) by leaving the SDA line high impedance (the external pull-up resistor will hold the line high). Change of data only occurs while the clock line (SCL) is low. DATA FORMAT After a Start condition, the master sends a 7-bit address followed by a read/write (R/W) bit. The R/W bit is 1 for a read request and 0 for a write request. If the 7-bit address matches the hard wired LTC2495's address (one of 27 pin-selectable addresses) the device is selected. When the device is addressed during the conversion state, it will not acknowledge R/W requests and will issue a NAK by leaving the SDA line high. If the conversion is complete, the LTC2495 issues an ACK by pulling the SDA line low.
SDA tf tLOW tr tSU(DAT) tf tHD(SDA) tSP tr tBUF
SCL tHD(SDA) S tSU(STA) Sr tSU(STO) P S
2495 F02
tHD(DAT)
tHIGH
Figure 2. Definition of Timing for Fast/Standard Mode Devices on the I2C Bus
2495f
14
LTC2495 APPLICATIONS INFORMATION
The LTC2495 has two registers. The output register (24 bits long) contains the last conversion result. The input register (16 bits long) sets the input channel, selects the temperature sensor, rejection mode, gain and speed mode. DATA OUTPUT FORMAT The output register contains the last conversion result. After each conversion is completed, the device automatically enters the sleep state where the supply current is reduced to 1A. When the LTC2495 is addressed for a read operation, it acknowledges (by pulling SDA low) and acts as a transmitter. The master/receiver can read up to three bytes from the LTC2495. After a complete read operation (3 bytes), a new conversion is initiated. The device will NAK subsequent read operations while a conversion is being performed. The data output stream is 24 bits long and is shifted out on the falling edges of SCL (see Figure 3a). The first bit is the conversion result sign bit (SIG) (see Tables 1 and 2). This bit is high if VIN 0 and low if VIN < 0 (where VIN corresponds to the selected input signal IN+ - IN-). The second bit is the most significant bit (MSB) of the result. The first two bits (SIG and MSB) can be used to indicate
Table 1. Output Data Format
Differential Input Voltage VIN* VIN* FS** FS** - 1LSB 0.5 * FS** 0.5 * FS** - 1LSB 0 -1LSB -0.5 * FS** -0.5 * FS** - 1LSB -FS** VIN* < -FS** Bit 23 SIG 1 1 1 1 1 0 0 0 0 0 Bit 22 MSB 1 0 0 0 0 1 1 1 1 0 Bit 21 0 1 1 0 0 1 1 0 0 1 Bit 20 0 1 0 1 0 1 0 1 0 1 Bit 19 0 1 0 1 0 1 0 1 0 1 ... ... ... ... ... ... ... ... ... ... ... Bit 6 LSB 0 1 0 1 0 1 0 1 0 1 Bits 5-0 Always 0 000000 000000 000000 000000 000000 000000 000000 000000 000000 000000
over and under range conditions (see Table 2). If both bits are HIGH, the differential input voltage is equal to or above +FS. If both bits are set low, the input voltage is below -FS. The function of these bits is summarized in Table 2. The 16 bits following the MSB bit are the conversion result in binary, two's complement format. The remaining six bits are always 0. As long as the voltage on the selected input channels (IN+ and IN-) remains between -0.3V and VCC + 0.3V (absolute maximum operating range) a conversion result is generated for any differential input voltage VIN from -FS = -0.5 * VREF/Gain to +FS = 0.5 * VREF /Gain. For differential input voltages greater than +FS, the conversion result is clamped to the value corresponding to +FS. For differential input voltages below -FS, the conversion result is clamped to the value -FS - 1LSB.
Table 2. LTC2495 Status Bits
Input Range VIN FS 0V VIN < FS -FS VIN < 0V VIN < -FS Bit 23 SIG 1 1 0 0 Bit 22 MSB 1 0 1 0
*The differential input voltage VIN = IN+ - IN-. **The full-scale voltage FS = 0.5 * VREF /Gain.
2495f
15
LTC2495 APPLICATIONS INFORMATION
INPUT DATA FORMAT The serial input word to the LTC2495 is 16 bits long and is written into the device input register in two 8-bit words. The first word (SGL, ODD, A2, A1, A0) is used to select the input channel. The second word of data (IM, FA, FB, SPD, GS2, GS1, GS0) is used to select the frequency rejection, speed mode (1x, 2x), temperature measurement, and gain. After power-up, the device initiates an internal reset cycle which sets the input channel to CH0-CH1 (IN+ = CH0, IN- = CH1), the frequency rejection to simultaneous 50Hz/60Hz, and 1x output rate (auto-calibration enabled), and gain = 1. The first conversion automatically begins at power-up using this default configuration. Once the conversion is complete, up to two words may be written into the device. The first three bits of the first input word consist of two preamble bits and one enable bit. Valid settings for these three bits are 000, 100, and 101. Other combinations should be avoided.
SCL 1 ... 7 8 9 1 2 ... 9
If the first three bits are 000 or 100, the following data is ignored (don't care) and the previously selected input channel and configuration remain valid for the next conversion. If the first three bits shifted into the device are 101, then the next five bits select the input channel for the next conversion cycle (see Table 3). The first input bit (SGL) following the 101 sequence determines if the input selection is differential (SGL = 0) or single-ended (SGL = 1). For SGL = 0, two adjacent channels can be selected to form a differential input. For SGL = 1, one of 16 channels is selected as the positive input. The negative input is COM for all single-ended operations. The remaining four bits (ODD, A2, A1, A0) determine which channel(s) is/are selected and the polarity (for a differential input). Once the first word is written into the device, a second word may be input in order to select a configuration mode.
1
2
3
4
5
6
7
8
9
SDA 7-BIT ADDRESS R ACK BY LTC2497 SLEEP SGN MSB BIT 21 ACK BY MASTER DATA OUTPUT
2495 F03a
LSB ALWAYS LOW NAK BY MASTER
START BY MASTER
Figure 3a. Timing Diagram for Reading from the LTC2495
SCL 1 2 ... 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
SDA 7-BIT ADDRESS W ACK BY LTC2495 SLEEP 1 0 EN SGL ODD A2 A1 A0 ACK LTC2495 DATA INPUT
2495 F03b
EN2
IM
FA
FB
SPD GS2 GS1 GS0 ACK LTC2495
(OPTIONAL 2ND BYTE)
START BY MASTER
Figure 3b. Timing Diagram for Writing to the LTC2495
2495f
16
LTC2495 APPLICATIONS INFORMATION
Table 3. Channel Selection
MUX ADDRESS ODD/ SGL SIGN *0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 A2 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 A1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 A0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN- IN- IN- IN- IN- IN- IN- IN- IN- IN- IN- IN- IN- IN- IN- 0 IN+ 1 IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- IN+ IN- 2 3 4 5 6 CHANNEL SELECTION 7 8 9 10 11 12 13 14 15 COM
*Default at power up
2495f
17
LTC2495 APPLICATIONS INFORMATION
The first bit of the second word is the enable bit for the conversion configuration (EN2). If this bit is set to 0, then the next conversion is performed using the previously selected converter configuration. If the EN2 bit is set to a 1, a new configuration can be loaded into the device (see Table 4). The first bit (IM) is used to select the internal temperature sensor. If IM = 1, the following conversion will be performed on the internal temperature sensor rather than the selected input channel. The next two bits (FA and FB) are used to set the rejection frequency. The next bit (SPD) is used to select either the 1x output rate if SPD = 0 (auto-calibration is enabled and the offset is continuously calibrated and removed from the final conversion result) or the 2x output rate if SPD = 1 (offset calibration disabled, multiplexing output rates up to 15Hz with no latency). The final three bits (GS2, GS1,
Table 4. Converter Configuration
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 EN SGL ODD A2 A1 A0 EN2 X 0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Any 1 1 Input Channel 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 IM X X 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 FA X X FB X X SPD X X 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Any Speed X X X X X X X X GS2 GS1 GS0 X X X X X X 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 Any Gain X X X X X X X X CONVERTER CONFIGURATION Keep Previous Keep Previous External Input, Gain = 1, Autocalibration External Input, Gain = 4, Autocalibration External Input, Gain = 8, Autocalibration External Input, Gain = 16, Autocalibration External Input, Gain = 32, Autocalibration External Input, Gain = 64, Autocalibration External Input, Gain = 128, Autocalibration External Input, Gain = 264, Autocalibration External Input, Gain = 1, 2x Speed External Input, Gain = 2, 2x Speed External Input, Gain = 4, 2x Speed External Input, Gain = 8, 2x Speed External Input, Gain = 16, 2x Speed External Input, Gain = 32, 2x Speed External Input, Gain = 64, 2x Speed External Input, Gain = 128, 2x Speed External Input, Simultaneous 50Hz/60Hz Rejection External Input, 50Hz Rejection External Input, 60Hz Rejection Reserved, Do Not Use Temperature Input, Simultaneous 50Hz/60Hz Rejection Temperature Input, 50Hz Rejection Temperature Input, 60Hz Rejection Reserved, Do Not Use
GS0) are used to set the gain. When IM = 1 (temperature measurement) SPD, GS2, GS1 and GS0 will be ignored and the device will operate in 1x mode. The configuration remains valid until a new input word with EN = 1 (the first three bits are 101 for the first word) and EN2 = 1 (for the second write byte) is shifted into the device. Rejection Mode (FA, FB) The LTC2495 includes a high accuracy on-chip oscillator with no required external components. Coupled with an integrated fourth order digital low pass filter, the LTC2495 rejects line frequency noise. In the default mode, the LTC2495 simultaneously rejects 50Hz and 60Hz by at least 87dB. If more rejection is required, the LTC2495 can be configured to reject 50Hz or 60Hz to better than 110dB.
Any Rejection Mode
0 0 1 1 0 0 1 1
0 1 0 1 0 1 0 1
2495f
18
LTC2495 APPLICATIONS INFORMATION
Speed Mode (SPD) Every conversion cycle, two conversions are combined to remove the offset (default mode). This result is free from offset and drift. In applications where the offset is not critical, the auto-calibration feature can be disabled with the benefit of twice the output rate. While operating in the 2x mode (SPD = 1), the linearity and full-scale errors are unchanged from the 1x mode performance. In both the 1x and 2x mode there is no latency. This enables input steps or multiplexer changes to settle in a single conversion cycle, easing system overhead and increasing the effective conversion rate. During temperature measurements, the 1x mode is always used independent of the value of SPD. GAIN (GS2, GS1, GS0) The input referred gain of the LTC2495 is adjustable from 1 to 256 (see Tables 5a and 5b). With a gain of 1, the differential input range is VREF/2 and the common mode input range is rail-to-rail. As the gain is increased, the differential input range is reduced to 0.5 * VREF/Gain but the common mode input range remains rail-to-rail. As the differential gain is increased, low level voltages are digitized with greater resolution. At a gain of 256, the LTC2495 digitizes an input signal range of 9.76mV with over 16,000 counts. Temperature Sensor The LTC2495 includes an integrated temperature sensor. The temperature sensor is selected by setting IM = 1. During temperature readings, MUXOUTN/ MUXOUTP remains connected to the selected input channel. The ADC internally connects to the temperature sensor and performs a conversion. The digital output is proportional to the absolute temperature of the device. This feature allows the converter to perform cold junction compensation for external thermocouples or continuously remove the temperature effects of external sensors. The internal temperature sensor output is 28mV at 27C (300K), with a slope of 93.5V/C independent of VREF (see Figures 4 and 5). Slope calibration is not required if the reference voltage (VREF) is known. A 5V reference has a slope of 2.45 LSBs16/C. The temperature is calculated from the output code (where DATAOUT16 is the decimal representation of the 16-bit result) for a 5V reference using the following formula: TK = DATAOUT16 in Kelvin 2 . 45
Table 5a. Performance vs Gain in Normal Speed Mode (VCC = 5V, VREF = 5V)
GAIN Input Span LSB Noise Free Resolution* Gain Error Offset Error 1 2.5 38.1 65536 5 0.5 4 0.625 9.54 65536 5 0.5 8 0.312 4.77 65536 5 0.5 16 0.156 2.38 65536 5 0.5 32 78m 1.19 65536 5 0.5 64 39m 0.596 65536 5 0.5 128 19.5m 0.298 32768 5 0.5 256 9.76m 0.149 16384 8 0.5 UNIT V V Counts ppm of FS V
Table 5b. Performance vs Gain in 2x Speed Mode (VCC = 5V, VREF = 5V)
GAIN Input Span LSB Noise Free Resolution* Gain Error Offset Error 1 2.5 38.1 65536 5 200 2 1.25 19.1 65536 5 200 4 0.625 9.54 65536 5 200 8 0.312 4.77 65536 5 200 16 0.156 2.38 65536 5 200 32 78m 1.19 65536 5 200 64 39m 0.596 45875 5 200 128 19.5m 0.298 22937 5 200 UNIT V V Counts ppm of FS V
2495f
*The resolution in counts is calculated as the FS divided by LSB or the RMS noise value, whichever is larger.
19
LTC2495 APPLICATIONS INFORMATION
If a different value of VREF is used, the temperature output is: DATAOUT16 TK = in Kelvin (0 . 49 * VREF ) If the value of VREF is not known, the slope is determined by measuring the temperature sensor at a known temperature TN (in K) and using the following formula: SLOPE = DATAOUT16 TN All Kelvin temperature readings can be converted to TC (C) using the fundamental equation: TC = TK - 273 Initiating a New Conversion When the LTC2495 finishes a conversion, it automatically enters the sleep state. Once in the sleep state, the device is ready for a read operation. After the device acknowledges a read request, the device exits the sleep state and enters the data output state. The data output state concludes and the LTC2495 starts a new conversion once a Stop condition is issued by the master or all 24 bits of data are read out of the device. During the data read cycle, a Stop command may be issued by the master controller in order to start a new conversion and abort the data transfer. This Stop command must be issued during the ninth clock cycle of a byte read when the bus is free (the ACK/NAK cycle). LTC2495 Address The LTC2495 has three address pins (CA0, CA1, CA2). Each may be tied high, low, or left floating enabling one of 27 possible addresses (see Table 6). In addition to the configurable addresses listed in Table 6, the LTC2495 also contains a global address (1110111) which may be used for synchronizing multiple LTC2495s or other LTC24XX delta-sigma I2C devices (see Synchronizing Multiple LTC2495s with a Global Address Call section). Operation Sequence
5 4 3 ABSOLUTE ERROR (C) 2 1 0 -1 -2 -3 -4 -5 -55 -30 -5 20 45 70 TEMPERATURE (C) 95 120
2495 F05
This value of slope can be used to calculate further temperature readings using: TK = DATAOUT16 SLOPE
1050 VCC = 5V VREF = 5V 900 SLOPE = 2.45 LSB /K 16 750 DATAOUT16 600 450 300 150 0
0
100
200 300 TEMPERATURE (K)
400
2495 F04
Figure 4. Internal PTAT Digital Output vs Temperature
The LTC2495 acts as a transmitter or receiver, as shown in Figure 6. The device may be programmed to perform several functions. These include input channel selection, measure the internal temperature, selecting the line frequency rejection (50Hz, 60Hz, or simultaneous 50Hz and 60Hz), a 2x speed mode and gain. Continuous Read In applications where the input channel/configuration does not need to change for each cycle, the conversion can be continuously performed and read without a write cycle (see Figure 7). The configuration/input channel remains
2495f
Figure 5. Absolute Temperature Error
20
LTC2495 APPLICATIONS INFORMATION
Table 6. Address Assignment
CA2 LOW LOW LOW LOW LOW LOW LOW LOW LOW HIGH HIGH HIGH HIGH HIGH HIGH HIGH HIGH HIGH FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT FLOAT CA1 LOW LOW LOW HIGH HIGH HIGH FLOAT FLOAT FLOAT LOW LOW LOW HIGH HIGH HIGH FLOAT FLOAT FLOAT LOW LOW LOW HIGH HIGH HIGH FLOAT FLOAT FLOAT CA0 LOW HIGH FLOAT LOW HIGH FLOAT LOW HIGH FLOAT LOW HIGH FLOAT LOW HIGH FLOAT LOW HIGH FLOAT LOW HIGH FLOAT LOW HIGH FLOAT LOW HIGH FLOAT ADDRESS 0010100 0010110 0010101 0100110 0110100 0100111 0010111 0100101 0100100 1010110 1100100 1010111 1110100 1110110 1110101 1100101 1100111 1100110 0110101 0110111 0110110 1000111 1010101 1010100 1000100 1000110 1000101
unchanged from the last value written into the device. If the device has not been written to since power up, the configuration is set to the default value. At the end of a read operation, a new conversion automatically begins. At the conclusion of the conversion cycle, the next result may be read using the method described above. If the conversion cycle is not concluded and a valid address selects the device, the LTC2495 generates a NAK signal indicating the conversion cycle is in progress. Continuous Read/Write Once the conversion cycle is concluded, the LTC2495 can be written to and then read from using the Repeated Start (Sr) command. Figure 8 shows a cycle which begins with a data Write, a repeated Start, followed by a Read and concluded with a Stop command. The following conversion begins after all 24 bits are read out of the device or after a Stop command. The following conversion will be performed using the newly programmed data. In cases where the same speed (1x/2x mode), rejection frequency (50Hz, 60Hz, 50Hz and 60Hz) and gain is used but the channel is changed, a Stop or Repeated Start may be issued after the first byte (channel selection data) is written into the device. Discarding a Conversion Result and Initiating a New Conversion with Optional Write At the conclusion of a conversion cycle, a write cycle can be initiated. Once the write cycle is acknowledged, a Stop command will start a new conversion. If a new input
S
7-BIT ADDRESS CONVERSION SLEEP
R/W
ACK
DATA
Sr
DATA TRANSFERRING
P CONVERSION
2495 F05
DATA INPUT/OUTPUT
Figure 6. Conversion Sequence
S
7-BIT ADDRESS
R ACK
READ
P
S
7-BIT ADDRESS
R ACK
READ
P
CONVERSION CONVERSION SLEEP DATA OUTPUT SLEEP DATA OUTPUT CONVERSION
2495 F07
Figure 7. Consecutive Reading with the Same Input/Configuration
2495f
21
LTC2495 APPLICATIONS INFORMATION
S 7-BIT ADDRESS W ACK WRITE Sr 7-BIT ADDRESS R ACK READ P
CONVERSION
SLEEP
DATA INPUT
ADDRESS
DATA OUTPUT
CONVERSION
2495 F08
Figure 8. Write, Read, Start Conversion
S
7-BIT ADDRESS
W ACK
WRITE (OPTIONAL)
P
CONVERSION
SLEEP
DATA INPUT
CONVERSION
2495 F09
Figure 9. Start a New Conversion Without Reading Old Conversion Result
SCL SDA LTC2495 LTC2495 ... LTC2495
S
GLOBAL ADDRESS ALL LTC2495s IN SLEEP
W ACK
WRITE (OPTIONAL)
P CONVERSION OF ALL LTC2495s
DATA INPUT
2495 F10
Figure 10. Synchronize Multiple LTC2495s with a Global Address Call
channel or conversion configuration is required, this data can be written into the device and a Stop command will initiate the next conversion (see Figure 9). Synchronizing Multiple LTC2495s with a Global Address Call In applications where several LTC2495s (or other I2C delta-sigma ADCs from Linear Technology Corporation) are used on the same I2C bus, all converters can be synchronized through the use of a global address call. Prior to issuing the global address call, all converters must have completed a conversion cycle. The master then issues a Start, followed by the global address 1110111, and a write request. All converters will be selected and acknowledge the request. The master then sends a write byte (optional) followed by the Stop command. This will update the channel selection (optional) converter configuration (optional) and simultaneously initiate a start of conversion for all delta-sigma ADCs on the bus (see Figure 10). In order
to synchronize multiple converters without changing the channel or configuration, a Stop may be issued after acknowledgement of the global write command. Global read commands are not allowed and the converters will NAK a global read request. Driving the Input and Reference The input and reference pins of the LTC2495 are connected directly to a switched capacitor network. Depending on the relationship between the differential input voltage and the differential reference voltage, these capacitors are switched between these four pins. Each time a capacitor is switched between two of these pins, a small amount of charge is transferred. A simplified equivalent circuit is shown in Figure 11. When using the LTC2495's internal oscillator, the input capacitor array is switched at 123kHz. The effect of the charge transfer depends on the circuitry driving the
2495f
22
LTC2495 APPLICATIONS INFORMATION
IIN+ IN+ INPUT MULTIPLEXER 100 MUXOUTP ADCINP EXTERNAL CONNECTION INTERNAL SWITCH NETWORK 10k I IN+
() (
AVG
= I IN-
()
AVG
=
VIN(CM) - VREF(CM) 0.5 * REQ
I REF + IIN- 100 IN- MUXOUTN ADCINN 10k where :
)
1.5VREF + VREF(CM) - VIN(CM) 0.5 * REQ
(
)-
AVG
VIN2 VREF * REQ
VREF = REF + - REF - REF + - REF - VREF(CM) = 2 CEQ 12F VIN = IN+ - IN- , WHERE IN+ AND IN- ARE THE SELECTED INPUT CHANNELS IN+ - IN- VIN(CM) = 2 REQ = 2.71M INTERNAL OSCILLATOR 60Hz MODE REQ = 2.98M INTERNAL OSCILLATOR 50Hz/60Hz MODE REQ = 0.833 * 1012 /fEOSC EXTERNAL OSCILLATOR
IREF+ REF+
EXTERNAL CONNECTION 10k
IREF- 10k REF- SWITCHING FREQUENCY fSW = 123kHz INTERNAL OSCILLATOR fSW = 0.4 * fEOSC EXTERNAL OSCILLATOR
2495 F11
(
)
Figure 11. Equivalent Analog Input Circuit
input/reference pins. If the total external RC time constant is less than 580ns the errors introduced by the sampling process are negligible since complete settling occurs. Typically, the reference inputs are driven from a low impedance source. In this case, complete settling occurs even with large external bypass capacitors. The inputs (CH0-CH15, COM), on the other hand, are typically driven from larger source resistances. Source resistances up to 10k may interface directly to the LTC2495 and settle completely; however, the addition of external capacitors at the input terminals in order to filter unwanted noise (antialiasing) results in incomplete settling. The LTC2495 offers two methods of removing these errors. The first is automatic differential input current cancellation (Easy Drive) and the second is the insertion of an external buffer between the MUXOUT and ADCIN pins, thus isolating the input switching from the source resistance. Automatic Differential Input Current Cancellation In applications where the sensor output impedance is low (up to 10k with no external bypass capacitor or up to 500 with 0.001F bypass), complete settling of the
input occurs. In this case, no errors are introduced and direct digitization is possible. For many applications, the sensor output impedance combined with external input bypass capacitors produces RC time constants much greater than the 580ns required for 1ppm accuracy. For example, a 10k bridge driving a 0.1F capacitor has a time constant an order of magnitude greater than the required maximum. The LTC2495 uses a proprietary switching algorithm that forces the average differential input current to zero independent of external settling errors. This allows direct digitization of high impedance sensors without the need for buffers. The switching algorithm forces the average input current on the positive input (IIN+) to be equal to the average input current on the negative input (IIN-). Over the complete conversion cycle, the average differential input current (IIN+ - IIN-) is zero. While the differential input current is zero, the common mode input current (IIN+ + IIN-)/2 is proportional to the difference between the common mode input voltage (VIN(CM)) and the common mode reference voltage (VREF(CM)).
2495f
23
LTC2495 APPLICATIONS INFORMATION
In applications where the input common mode voltage is equal to the reference common mode voltage, as in the case of a balanced bridge, both the differential and common mode input current are zero. The accuracy of the converter is not compromised by settling errors. In applications where the input common mode voltage is constant but different from the reference common mode voltage, the differential input current remains zero while the common mode input current is proportional to the difference between VIN(CM) and VREF(CM). For a reference common mode voltage of 2.5V and an input common mode of 1.5V, the common mode input current is approximately 0.74A (in simultaneous 50Hz/60Hz rejection mode). This common mode input current does not degrade the accuracy if the source impedances tied to IN+ and IN- are matched. Mismatches in source impedance lead to a fixed offset error but do not effect the linearity or full-scale reading. A 1% mismatch in a 1k source resistance leads to a 74V shift in offset voltage. In applications where the common mode input voltage varies as a function of the input signal level (single-ended type sensors), the common mode input current varies proportionally with input voltage. For the case of balanced input impedances, the common mode input current effects are rejected by the large CMRR of the LTC2495, leading to little degradation in accuracy. Mismatches in source impedances lead to gain errors proportional to the difference between the common mode input and common mode reference. A 1% mismatch in 1k source resistances lead to gain errors on the order of 15ppm. Based on the stability of the internal sampling capacitors and the accuracy of the internal oscillator, a one-time calibration will remove this error. In addition to the input sampling current, the input ESD protection diodes have a temperature dependent leakage current. This current, nominally 1nA (10nA max), results in a small offset shift. A 1k source resistance will create a 1V typical and a 10V maximum offset voltage. Automatic Offset Calibration of External Buffers/ Amplifiers In addition to the Easy Drive input current cancellation, the LTC2495 allows an external amplifier to be inserted between the multiplexer output and the ADC input (see Figure 12). This is useful in applications where balanced source impedances are not possible. One pair of external buffers/amplifiers can be shared between all 17 analog inputs. The LTC2495 performs an internal offset calibration
LTC2495 ADC WITH EASY DRIVE INPUTS
ANALOG 17 INPUTS
INPUT MUX MUXOUTN MUXOUTP
SDA SCL
2
-
1/2 LTC6078 1
1k 0.1F
3
+
6
-
1/2 LTC6078 7
1k 0.1F
2495 F12
5
+
Figure 12. External Buffers Provide High Impedance Inputs and Amplifier Offsets are Automatically Cancelled.
2495f
24
LTC2495 APPLICATIONS INFORMATION
every conversion cycle in order to remove the offset and drift of the ADC. This calibration is performed through a combination of front end switching and digital processing. Since the external amplifier is placed between the multiplexer and the ADC, it is inside this correction loop. This results in automatic offset correction and offset drift removal of the external amplifier. The LTC6078 is an excellent amplifier for this function. It operates with supply voltages as low as 2.7V and its noise level is 18nV/Hz. The Easy Drive input technology of the LTC2495 enables an RC network to be added directly to the output of the LTC6078. The capacitor reduces the magnitude of the current spikes seen at the input to the ADC and the resistor isolates the capacitor load from the op-amp output enabling stable operation. The LTC6078 can also be biased at supply rails beyond those used by the LTC2495. This allows the external sensor to swing railto-rail (-0.3V to VCC + 0.3V) without the need of external level shift circuitry. Reference Current Similar to the analog inputs, the LTC2495 samples the differential reference pins (REF+ and REF-) transferring small amounts of charge to and from these pins, thus producing a dynamic reference current. If incomplete settling occurs (as a function the reference source resistance and reference bypass capacitance) linearity and gain errors are introduced.
90 80 70 +FS ERROR (ppm) 60 50 40 30 20 10 0 -10 0 10 1k 100 RSOURCE () 10k 100k
2495 F13
For relatively small values of external reference capacitance (CREF < 1nF), the voltage on the sampling capacitor settles for reference impedances of many k (if CREF = 100pF up to 10k will not degrade the performance (see Figures 13 and 14)). In cases where large bypass capacitors are required on the reference inputs (CREF > 0.01F), full-scale and linearity errors are proportional to the value of the reference resistance. Every ohm of reference resistance produces a full-scale error of approximately 0.5ppm (while operating in simultaneous 50Hz/60Hz mode (see Figures 15 and 16)). If the input common mode voltage is equal to the reference common mode voltage, a linearity error of approximately 0.67ppm per 100 of reference resistance results (see Figure 17). In applications where the input and reference common mode voltages are different, the errors increase. A 1V difference in between common mode input and common mode reference results in a 6.7ppm INL error for every 100 of reference resistance. In addition to the reference sampling charge, the reference ESD protection diodes have a temperature dependent leakage current. This leakage current, nominally 1nA (10nA max) results in a small gain error. A 100 reference resistance will create a 0.5V full-scale error.
-FS ERROR (ppm)
VCC = 5V VREF = 5V VIN+ = 3.75V VIN- = 1.25V FO = GND TA = 25C CREF = 0.01F CREF = 0.001F CREF = 100pF CREF = 0pF
10 0 -10 -20 -30 -40 -50 VCC = 5V -60 VREF = 5V V + = 1.25V -70 VIN- = 3.75V IN -80 FO = GND TA = 25C -90 10 0 CREF = 0.01F CREF = 0.001F CREF = 100pF CREF = 0pF
1k 100 RSOURCE ()
10k
100k
2495 F14
Figure 13. +FS Error vs RSOURCE at VREF (Small CREF)
Figure 14. -FS Error vs RSOURCE at VREF (Small CREF)
2495f
25
LTC2495 APPLICATIONS INFORMATION
500 400 +FS ERROR (ppm) VCC = 5V VREF = 5V VIN+ = 3.75V VIN- = 1.25V FO = GND TA = 25C 0 CREF = 1F, 10F -100 CREF = 0.1F -FS ERROR (ppm) INL (ppm OF VREF) CREF = 0.01F -200 CREF = 1F, 10F -300 VCC = 5V VREF = 5V VIN+ = 1.25V VIN- = 3.75V FO = GND TA = 25C 0 200 600 400 RSOURCE () CREF = 0.1F 10 VCC = 5V 8 VREF = 5V VIN(CM) = 2.5V 6 T = 25C A 4 CREF = 10F 2 0 -2 -4 -6 -8 800 1000
2495 F16
R = 1k
300
R = 500 R = 100
200 CREF = 0.01F 100
-400
0
-500 0 200 600 400 RSOURCE () 800 1000
2495 F15
-10 - 0.5
- 0.3
0.1 - 0.1 VIN/VREF
0.3
0.5
2495 F17
Figure 15. +FS Error vs RSOURCE at VREF (Large CREF)
Figure 16. -FS Error vs RSOURCE at VREF (Large CREF)
Figure 17. INL vs Differential Input Voltage and Reference Source Resistance for CREF > 1F
One of the advantages delta-sigma ADCs offer over conventional ADCs is on-chip digital filtering. Combined with a large oversample ratio, the LTC2495 significantly simplifies antialiasing filter requirements. Additionally, the input current cancellation feature allows external low pass filtering without degrading the DC performance of the device. The SINC4 digital filter provides excellent normal mode rejection at all frequencies except DC and integer multiples of the modulator sampling frequency (fS) (see Figures 18 and 19). The modulator sampling frequency is fS = 15,360Hz while operating with its internal oscillator and fS = fEOSC/20 when operating with an external oscillator of frequency fEOSC . When using the internal oscillator, the LTC2495 is designed to reject line frequencies. As shown in Figure 20, rejection nulls occur at multiples of frequency fN, where fN is determined by the input control bits FA and FB (fN = 50Hz or 60Hz or 55Hz for simultaneous rejection). Multiples of the modulator sampling rate (fS = fN * 256) only reject noise to 15dB (see Figure 21); if noise sources are present at these frequencies antialiasing will reduce their effects. The user can expect to achieve this level of performance using the internal oscillator, as shown in Figures 22, 23, and 24. Measured values of normal mode rejection are
INPUT NORMAL MODE REJECTION (dB)
Normal Mode Rejection and Antialiasing
0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120 0 fS 2fS 3fS 4fS 5fS 6fS 7fS 8fS 9fS 10fS11fS12fS DIFFERENTIAL INPUT SIGNAL FREQUENCY (Hz)
2495 F18
Figure 18. Input Normal Mode Rejection, Internal Oscillator and 50Hz Rejection Mode
0 INPUT NORMAL MODE REJECTION (dB) -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120 0 fS 2fS 3fS 4fS 5fS 6fS 7fS 8fS 9fS 10fS DIFFERENTIAL INPUT SIGNAL FREQUENCY (Hz)
2495 F19
Figure 19. Input Normal Mode Rejection, Internal Oscillator and 60Hz Rejection Mode
2495f
26
LTC2495 APPLICATIONS INFORMATION
0 INPUT NORMAL MODE REJECTION (dB) -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120 0 fN 2fN 3fN 4fN 5fN 6fN 7fN INPUT SIGNAL FREQUENCY (Hz) 8fN INPUT NORMAL MODE REJECTION (dB) fN = fEOSC/5120 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120 250fN 252fN 254fN 256fN 258fN 260fN 262fN INPUT SIGNAL FREQUENCY (Hz)
2495 F21
fN = fEOSC/5120
2495 F20
Figure 20. Input Normal Mode Rejection at DC
0 NORMAL MODE REJECTION (dB) -20 -40 - 60 -80 -100 -120
Figure 21. Input Normal Mode Rejection at fS = 256 * fN
VCC = 5V VREF = 5V VIN(CM) = 2.5V VIN(P-P) = 5V TA = 25C
MEASURED DATA CALCULATED DATA
0
15
30
45
60
75
90 105 120 135 150 165 180 195 210 225 240 INPUT FREQUENCY (Hz)
2495 F23
Figure 22. Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 100% (60Hz Notch)
0 NORMAL MODE REJECTION (dB) -20 -40 - 60 -80 -100 -120 MEASURED DATA CALCULATED DATA
VCC = 5V VREF = 5V VIN(CM) = 2.5V VIN(P-P) = 5V TA = 25C
0
12.5 25 37.5 50 62.5 75 87.5 100 112.5 125 137.5 150 162.5 175 187.5 200 INPUT FREQUENCY (Hz)
2495 F24
Figure 23. Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 100% (50Hz Notch)
2495f
27
LTC2495 APPLICATIONS INFORMATION
shown superimposed over the theoretical values in all three rejection modes. Traditional high order delta-sigma modulators suffer from potential instabilities at large input signal levels. The proprietary architecture used for the LTC2495 third order modulator resolves this problem and guarantees stability with input signals 150% of full scale. In many
0 NORMAL MODE REJECTION (dB) -20 -40 - 60 -80 -100 -120 MEASURED DATA CALCULATED DATA VCC = 5V VREF = 5V VIN(CM) = 2.5V VIN(P-P) = 5V TA = 25C
industrial applications, it is not uncommon to have microvolt level signals superimposed over unwanted error sources with several volts if peak-to-peak noise. Figures 25 and 26 show measurement results for the rejection of a 7.5V peak-to-peak noise source (150% of full scale) applied to the LTC2495. These curves show that the rejection performance is maintained even in extremely noisy environments.
0 NORMAL MODE REJECTION (dB) -20 -40 - 60 -80 -100 -120 VIN(P-P) = 5V VIN(P-P) = 7.5V (150% OF FULL SCALE) VCC = 5V VREF = 5V VIN(CM) = 2.5V TA = 25C
0
20
40
60
80 100 120 140 INPUT FREQUENCY (Hz)
160
180
200
220
2495 F25
0
15
30
45
60
75
90 105 120 135 150 165 180 195 210 225 240 INPUT FREQUENCY (Hz)
2495 F26
Figure 24. Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 100% (50Hz/60Hz Notch)
0 NORMAL MODE REJECTION (dB) -20 -40 - 60 -80 -100 -120
Figure 25. Measure Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 150% (60Hz Notch)
VIN(P-P) = 5V VIN(P-P) = 7.5V (150% OF FULL SCALE)
VCC = 5V VREF = 5V VIN(CM) = 2.5V TA = 25C
0
12.5 25 37.5 50 62.5 75 87.5 100 112.5 125 137.5 150 162.5 175 187.5 200 INPUT FREQUENCY (Hz)
2495 F27
Figure 26. Measure Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 150% (50Hz Notch)
2495f
28
LTC2495 APPLICATIONS INFORMATION
Using the 2X speed mode of the LTC2495 alters the rejection characteristics around DC and multiples of fS. The device bypasses the offset calibration in order to increase the output rate. The resulting rejection plots are shown in Figures 27 and 28. 1x type frequency rejection can be achieved using the 2x mode by performing a running average of the previoius two conversion results (see Figure 29). Output Data Rate When using its internal oscillator, the LTC2495 produces up to 15 samples per second (sps) with a notch frequency of 60Hz. The actual output data rate depends upon the length of the sleep and data output cycles which are controlled by the user and can be made insignificantly short. When operating with an external conversion clock (FO connected to an external oscillator), the LTC2495 output data rate can be increased. The duration of the conversion cycle is 41036/fEOSC. If fEOSC = 307.2kHz, the converter behaves as if the internal oscillator is used. An increase in fEOSC over the nominal 307.2kHz will translate into a proportional increase in the maximum output data rate (up to a maximum of 100sps). The increase in
0 INPUT NORMAL REJECTION (dB) INPUT NORMAL REJECTION (dB) 0 fN 2fN 3fN 4fN 5fN 6fN 7fN INPUT SIGNAL FREQUENCY (fN) 8fN -20 -40 -60 -80
output rate leads to degradation in offset, full-scale error, and effective resolution as well as a shift in frequency rejection. When using the integrated temperature sensor, the internal oscillator should be used or an external oscillator fEOSC = 307.2kHz maximum. A change in fEOSC results in a proportional change in the internal notch position. This leads to reduced differential mode rejection of line frequencies. The common mode rejection of line frequencies remains unchanged, thus fully differential input signals with a high degree of symmetry on both the IN+ and IN - pins will continue to reject line frequency noise. An increase in fEOSC also increases the effective dynamic input and reference current. External RC networks will continue to have zero differential input current, but the time required for complete settling (580ns for fEOSC = 307.2kHz) is reduced, proportionally. Once the external oscillator frequency is increased above 1MHz (a more than 3x increase in output rate) the effectiveness of internal auto calibration circuits begins to degrade. This results in larger offset errors, full-scale errors, and decreased resolution, as seen in Figures 30 to 37.
0 -20 -40 -60 -80 -100 -120 248 250 252 254 256 258 260 262 264 INPUT SIGNAL FREQUENCY (fN)
2495 F28
-100 -120
2495 F27
Figure 27. Input Normal Mode Rejection 2x Speed Mode
Figure 28. Input Normal Mode Rejection 2x Speed Mode
2495f
29
LTC2495 APPLICATIONS INFORMATION
-70 NORMAL MODE REJECTION (dB) -80 NO AVERAGE -90 -100 -110 -120 -130 -140 60 62 54 56 58 48 50 52 DIFFERENTIAL INPUT SIGNAL FREQUENCY (Hz)
2495 F29
50 40 30
OFFSET ERROR (ppm OF VREF)
+FS ERROR (ppm OF VREF)
VIN(CM) = VREF(CM) VCC = VREF = 5V VIN = 0V FO = EXT CLOCK TA = 85C
3500 3000 2500
VIN(CM) = VREF(CM) VCC = VREF = 5V FO = EXT CLOCK
TA = 85C 2000 1500 1000 500 0 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 F31
WITH RUNNING AVERAGE
20 10 0 TA = 25C
TA = 25C
-10 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 F30
Figure 29. Input Normal Mode Rejection 2x Speed Mode with and Without Running Averaging
0 -500 -FS ERROR (ppm OF VREF) 18
Figure 30. Offset Error vs Output Data Rate and Temperature
Figure 31. +FS Error vs Output Data Rate and Temperature
18 TA = 25C, 85C
RESOLUTION (BITS)
TA = 25C TA = 85C -2000
RESOLUTION (BITS)
-1000
16
16 TA = 85C 14
TA = 25C
-1500
14
-2500 -3000 -3500 VIN(CM) = VREF(CM) VCC = VREF = 5V FO = EXT CLOCK 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 F32
12
VIN(CM) = VREF(CM) VCC = VREF = 5V VIN = 0V FO = EXT CLOCK RES = LOG 2 (VREF/NOISERMS) 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 F33
10
12 VIN(CM) = VREF(CM) VCC = VREF = 5V FO = EXT CLOCK RES = LOG 2 (VREF/INLMAX) 10 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 F34
Figure 32.-FS Error vs Output Data Rate and Temperature
20
Figure 33. Resolution (NoiseRMS 1LSB) vs Output Data Rate and Temperature
18
Figure 34. Resolution (INLMAX 1LSB) vs Output Data Rate and Temperature
18
OFFSET ERROR (ppm OF VREF)
VIN(CM) = VREF(CM) VIN = 0V 15 FO = EXT CLOCK TA = 25C RESOLUTION (BITS) 10 VCC = VREF = 5V 5 0 -5 VCC = 5V, VREF = 2.5V
VCC = 5V, VREF = 2.5V, 5V 14
RESOLUTION (BITS)
16
16 VCC = 5V, VREF = 2.5V 14
VCC = VREF = 5V
-10 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 F35
VIN(CM) = VREF(CM) 12 VIN = 0V FO = EXT CLOCK TA = 25C RES = LOG 2 (VREF/NOISERMS) 10 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 F36
VIN(CM) = VREF(CM) VIN = 0V 12 REF- = GND FO = EXT CLOCK TA = 25C RES = LOG 2 (VREF/INLMAX) 10 0 10 20 30 40 50 60 70 80 90 100 OUTPUT DATA RATE (READINGS/SEC)
2495 F37
Figure 35. Offset Error vs Output Data Rate and Temperature
Figure 36. Resolution (NoiseRMS 1LSB) vs Output Data Rate and Temperature
Figure 37. Resolution (INLMAX 1LSB) vs Output Data Rate and Temperature
2495f
30
LTC2495 PACKAGE DESCRIPTION
UHF Package 38-Lead Plastic QFN (5mm x 7mm) (Reference LTC DWG # 05-08-1701)
0.70 0.05
5.50 0.05 (2 SIDES) 4.10 0.05 (2 SIDES) 3.15 0.05 (2 SIDES)
PACKAGE OUTLINE 0.25 0.05 0.50 BSC 5.15 0.05 (2 SIDES) 6.10 0.05 (2 SIDES) 7.50 0.05 (2 SIDES) RECOMMENDED SOLDER PAD LAYOUT 5.00 0.10 (2 SIDES) 0.75 0.05 0.00 - 0.05 3.15 0.10 (2 SIDES) PIN 1 NOTCH R = 0.30 TYP OR 0.35 x 45 CHAMFER 37 38 0.40 0.10 1 2
PIN 1 TOP MARK (SEE NOTE 6)
7.00 0.10 (2 SIDES)
5.15 0.10 (2 SIDES)
0.40 0.10 0.200 REF 0.25 0.05 0.75 0.05 0.200 REF 0.00 - 0.05 0.50 BSC R = 0.115 TYP
(UH) QFN 0205
BOTTOM VIEW--EXPOSED PAD
NOTE: 1. DRAWING CONFORMS TO JEDEC PACKAGE OUTLINE M0-220 VARIATION WHKD 2. DRAWING NOT TO SCALE 3. ALL DIMENSIONS ARE IN MILLIMETERS
4. DIMENSIONS OF EXPOSED PAD ON BOTTOM OF PACKAGE DO NOT INCLUDE MOLD FLASH. MOLD FLASH, IF PRESENT, SHALL NOT EXCEED 0.20mm ON ANY SIDE 5. EXPOSED PAD SHALL BE SOLDER PLATED 6. SHADED AREA IS ONLY A REFERENCE FOR PIN 1 LOCATION ON THE TOP AND BOTTOM OF PACKAGE
2495f
Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights.
31
LTC2495 TYPICAL APPLICATION
External Buffers Provide High Impedance Inputs and Amplifier Offsets are Automatically Cancelled
LTC2495 MUXOUTN MUXOUTP ANALOG 17 INPUTS INPUT MUX
ADC WITH EASY DRIVE INPUTS
SDA SCL
2
-
1/2 LTC6078 1
1k 0.1F
3
+
6
-
1/2 LTC6078 7
1k 0.1F
2495 TA03
5
+
RELATED PARTS
PART NUMBER LT1236A-5 LT1460 LT1790 LTC2400 LTC2410 LTC2411/ LTC2411-1 LTC2413 LTC2440 LTC2442 LTC2449 LTC2480/LTC2482/ LTC2484 LTC2481/LTC2483/ LTC2485 LTC2496 LTC2497 LTC2498 LTC2499 DESCRIPTION Precision Bandgap Reference, 5V Micropower Series Reference Micropower SOT-23 Low Dropout Reference Family 24-Bit, No Latency ADC in SO-8 24-Bit, No Latency ADC with Differential Inputs 24-Bit, No Latency ADCs with Differential Inputs in MSOP 24-Bit, No Latency ADC with Differential Inputs 24-Bit, High Speed, Low Noise ADC 24-Bit, High Speed, 2-/4-Channel ADC with Integrated Amplifier 24-Bit, High Speed, 8-/16-Channel ADC 16-Bit/24-Bit ADCs with Easy Drive Inputs, 600nV Noise, Programmable Gain, and Temperature Sensor 16-Bit/24-Bit ADCs with Easy Drive Inputs, 600nV Noise, I2C Interface, Programmable Gain, and Temperature Sensor 16-Bit 8-/16-Channel ADC with Easy Drive Inputs and SPI Interface 16-Bit 8-/16-Channel ADC with Easy Drive Inputs and I2C Interface 24-Bit 8-/16-Channel ADC with Easy Drive Inputs and SPI Interface, Temperature Sensor 24-Bit 8-/16-Channel ADC with Easy Drive Inputs and I2C Interface COMMENTS 0.05% Max Initial Accuracy, 5ppm/C Drift 0.075% Max Initial Accuracy, 10ppm/C Max Drift 0.05% Max Initial Accuracy, 10ppm/C Max Drift 0.3ppm Noise, 4ppm INL, 10ppm Total Unadjusted Error, 200A 0.8VRMS Noise, 2ppm INL 1.45VRMS Noise, 4ppm INL, Simultaneous 50Hz/60Hz Rejection (LTC2411-1) Simultaneous 50Hz/60Hz Rejection, 800nVRMS Noise 3.5kHz Output Rate, 200nV Noise, 24.6 ENOBs 8kHz Output Rate, 200nV Noise, Simultaneous 50Hz/60Hz Rejection 8kHz Output Rate, 200nV Noise, Simultaneous 50Hz/60Hz Rejection Pin Compatible with 16-Bit and 24-Bit Versions Pin Compatible with 16-Bit and 24-Bit Versions Pin Compatible with LTC2498/LTC2449 Pin Compatible with LTC2495/LTC2499 Pin Compatible with LTC2496/LTC2449 Pin Compatible with LTC2495/LTC2497
2495f
32 Linear Technology Corporation
(408) 432-1900 FAX: (408) 434-0507
LT 0107 * PRINTED IN USA
1630 McCarthy Blvd., Milpitas, CA 95035-7417
www.linear.com
(c) LINEAR TECHNOLOGY CORPORATION 2007


▲Up To Search▲   

 
Price & Availability of LTC2495CUHF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X